Company Info

Basic Info.

Model NO.
50KW, 100KW, 250KW, 500KW
Condition
New
Certification
CE
Application
Home, Industrial, Commercial
Specification
Big, 50KW, 100KW, 250KW, 500KW
Trademark
Daseon
Transport Package
Wood Case
Origin
China
HS Code
85044020

Product Description

Commercial & Industrial Energy Storage Solutions

Compatible with various batteries.
Customizable separate battery space
Working with external EMS for remote control 
 
Bi-directional Storage Inverter List 
PCS1-50K PCS1-100K PCS1-150K PCS2-50K PCS2-100K PCS1-250K PCS1-500K
DC PORT - BATTERY
Battery Voltage
Range 
500-800V 250-520V 500-800V 630-900V
Max. Current 110A 220A 330A 150A 300A 550A 873A
Max. Power 55kW 110kW 165kW 50kW 100kW 275kW 500kW
Charging
methods 
Constant current and/or constant power, configurable 3-steps charging (Fast-slow-trickle)      
Charging
response time 
From 0A to Max ≤ 50ms; Switching from charging to discharging at full load ≤ 80ms      
DC PORT - PV       
PV VoltageN/A500~900VN/A    
PV Max Current 110A 220A      
PV Max Power 55kW 110kW     
AC GRID       
Rated Output
Power 
50kW 100kW 150kW 50kW 100kW 250kW 500kW
Rated Voltage 480V OR 380/400V 400V     
Voltage Range -15% to +10% OR -15% to +15% -15% to +15%     
Frequency 60Hz OR 50/60Hz 50/60Hz     
Frequency
Range 
±0.5Hz or configurable      
Rated Current 60A OR 72/76A 120A OR
144/152A
180A OR
228/216A 
60A OR 72/76A 144/152A 120A OR 380/360A 300A OR 760A/720A
Overload
Capability 
1.05      
Output THDi ≤ 3%      
Power Factor -1~+1      
AC LOAD       
Voltage 480V OR 380/400V 400V     
Voltage Range ±5% ±10%     
Frequency 60Hz OR 50/60Hz 50Hz/60Hz     
Output Overload
Capability 
105%~115% >10min; 115%~125% > 1min ; 125%~150% > 200ms      
Auto Transfer
Switch Module 
Optional Optional Cabinet     
On-grid/Off-grid
Transfer Time 
15ms to 80ms      
SYSTEM       
Peak. Efficiency 96.10% 98.20%     
Protection OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, Anti-islanding (on/off),Configurable
Limit: Upper/Lower AC Voltage/Frequency limit, Battery EOD voltage.
      
Installation Floor-standing      
AC Connection 3P+N+PE 3P+PE     
Isolation Built-in Transformer Non-isolation     
Cooling Forced air cooling with replaceable fan module      
Noise <65dB      
Working Temp. -20C to 50C      
Enclosure IP20/NEMA1      
Max Elevation 3000m/10000feet (De-rating after 2000m/6500feet)      
Humidity 0~95%      
Size (W*H*D) 800*2160*800 (mm) / 31.5*85*31.5 (inches)1200*2160*800(mm)
/ 47.3*85*31.5
(Inches)
1100*2160*800(mm)
/ 43.3*85*31.5
(Inches)
    
Weight 450Kgs/990Lbs 550Kgs/1210Lbs 780Kgs/1720Lbs 500Kgs/1100Lbs 650Kgs/1435Lbs 1300Kgs/2870Lbs 600Kgs/1320Lbs
COMMUICATION       
Display Touch Screen      
Protocol ModBus, MESA      
Socket RJ45, CAN, Ethernet      
STANDARD & COMPLIANCE       
Safety UL9540, UL1741, Rule21 / IEC62109-1/2      
Grid IEEE1547 / VDE-2106 / UL1741SA / HECO / RULE21      
EMC FCC Part15 Class A, CSA C22.2 No107.1 / IEC61000-6-2, IEC61000-6-4      
 
Why?
how?
PCS : Hybrid storage inverter , or storage inverter, or modular PV
inverter and storage inverter
Distribution box
Battery cabinet from battery vendor or separate space for
battery bank & BMS
Optional cabinet
Frequency Response
To participate enhanced or fast frequency response requested
by utility .
Demand Response
Working with external energy management system (EMS ) to
participate on peak shaving and be benefit from peak and off -
peak price difference and saving on demand charge.
Micro -grid
To operate as DC or AC micro -grid with external wind mill and
or diesel gen -set.
Power Distribution Extension
To skip the upgrade on existing distribution network and
accomplish extension of power distribution in short time to
meet the fast growth of demand , such as EV charger
installation and launches of new commercial and industrial
activities .
Renewable Energy Maximization
To maximize the renewable energy generated by PV and /or
wind by storing over -generated energy into battery bank for
future use .
Flexible
Modular design and wide power range in single cabinet .
Built-in transformer for direct grid connection or transformer -
less design allows customized system design .
Indoor use or out -door application within container
Multiple DC connections enables use of battery strings with
different voltage level at the same time and the use of used
battery bank or new one .
Optional STS offers seamless switch between on -grid and off -
grid.
Reliable
15MW+ installation globally
Siemens power module
Redundant modular design limited stop of energy storage
system .
Independent air tunnel for cooling on heat components
extends life time .
Front service only , easy to maintain and fast replaceable.
Compatible
Grid -interactive and off -grid operation by same device .
Used under different voltage level and grid by changing
transformer .
Support on various chemical technology of Lead -carbon ,
Lithium -ion, Flow battery and super capacitor .
Used for ccommunity residential , commercial and industrial
applications .
Succeed in cases for grid support , demand response , micro -
grid, and renewable energy maximization . 

 

 
Send your message to this supplier
Mr. Jackson

Post a Sourcing Request Now

People who liked this also liked